Datacomtools.com
TM
Free Ground Shipping on Orders over $99.00. In the contiguous states, certain items may not apply
MultiFiber Pro Optical Power Meter and Fiber Test Kits
Data centers are growing, fueled by the proliferation of media, virtualization and the need for more
security and storage. This creates a high demand for 40 Gbps+ ber links. Whether it is using 10
Gbps pre-terminated ber trunks or planning for next-generation 40/100 Gbps performance, data
centers are standardizing on Multi-ber Push-on (MPO) connector solutions.
“SCAN ALL” Function: Scan All function in the MultiFiber Pro Power Meter automatically scans and
tests all 12 bers in MPO connectors taking just 6 seconds to complete all loss or power
measurements. This feature automates the testing of MPO terminated bers and eliminates the
time consuming and manual process of moving the tester from ber to ber while using fan-out
cords.
Built-in Polarity Verication: The simple purpose of any polarity scheme is to provide a
continuous connection from the link’s transmitter to the link’s receiver. For array connectors,
TIA-568-C.0 denes three methods to accomplish this. The polarity measurement of MultiFiber Pro
allows the user to test individual patch cords, permanent links, and channels for correct polarity.
On-board MPO connector: The MPO connector on both the OPM and OLS eliminates the use of
costly & complicated fan-out cords to test MPO ber trunks.
Simple User Interface: Simplies the task of simultaneously presenting polarity, power, and loss
results for 12 bers. The power meter enables the users to easily comprehend the measurement
results of 12 bers simultaneously. The light source identies each ber within the MPO connector
being tested. Any individual measurements that fail the test limit is identied to allow root-cause
analysis. This powerful yet straightforward test set enables everyone to become a ber testing
expert increasing efciency in testing data center projects.
Environmental
Operating temperature -10ºC to +50ºC
Storage temperature -20ºC to +50ºC
Operating humidity 95% (10ºC to +35ºC) non-condensing
75% (35ºC to +45ºC) non-condensing
Uncontrolled <10ºC
Operating altitude 4,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz
Optical Power Meter (Specications apply at 23ºC (73ºF), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement range 0 dBm to -50 dBm
Power measurement linearity ±0.1 dB1
Power measurement uncer-
tainty
±0.35 dB
Power measurement repeat-
ability
< 0.10 dB
Display resolution, dB or dBm 0.01
Power display units dBm, mW, μW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0
dB and 0.1 dB up to 50.0 dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal
Systems polarities
2 kHz detection Yes
Record storage 3000 records, one ber per record (250 12-ber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-ber, unpinned plugs. Compatible
with 62.5 μm, 50 μm, and singlemode bers. Connector
has a self-closing, protective cover.
Power requirement 2 AA alkaline batteries
Battery life2 >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.7 in x 3.2 in x 1.5 in
Weight 10.9 oz (309 g)
850nm Source (Specications apply at 23ºC (73ºF), unless otherwise noted)
Emitter type LED: 850 nm
Wavelength 850 nm: ±30 nm
Spectral width (FWHM) 850 nm: +/- 50 nm (typical)
Output power 850 nm: ≥24 dBm. Max difference between channels
+/-1dB
Power output stability3 ≤ ±0.1 dB over 8 hours
Encircled ux Meets ANSI/TIA-526-14-B, ISO/IEC 14763-3, and IEC
61280-4-1 for 50/125 μm at the source’s optical con-
nector.
Optical connector MPO interface for 12-ber, unpinned plugs. Compatible
with 62.5 μm and 50 μm.
Model Description
MFTK1200 MultiFiber Pro Testing Base Kit includes MultiFiber Pro
Power Meter, 850 light source, test cords, MPO adapt-
ers, MPO OneClick Cleaner, and carrying case
$9995.00
MFTK1400 MultiFiber Pro Testing and Inspection Kit includes
MFTK1200, FT600 FiberInspector Pro with NF370
MPO tip
$13995.00
MFPOWERMETER MultiFiber Pro Optical Power Meter $5995.00
MFMULTIMODE-
SOURCE
MultiFiber Pro Mulitmode 850 nm LED light source $4995.00
FT600 FiberInspector Pro $3780.00
NF370 MPO Fiber Inspection Adapter Tip for FT600 $1075.00
TRC-MPO-PP-B 1 m test cord with MPO/MPO, Pinned/Pinned, Type B
polarity
$280.00
TRC-MPO-UP-B 1 m test cord with MPO/MPO, Unpinned/Pinned, Type
B polarity
$280.00
TRC-MPO-UU-B 0.3 m test cord with MPO/MPO, Unpinned/Unpinned,
Type B polarity
$280.00
BKC-MPO-ULC 1 m breakout cord for MPO Unpinned LC connector $900.00
BKC-MPO-USC 1 m breakout cord for MPO Unpinned SC connector $900.00
ADP-MPO-B Type B polarity MPO adapter $30.00
GLD-MF 1 YR GOLD for MFPOWERMETER/MFMULTIMODE-
SOURCE
$1212.00
GLD-MFTK 1 YR GOLD for MFTK1200, MFTK1400 $1752.00
NFC-IBC-1.25mm OneClick cleaners for 1.25 mm LC and MU connector
and patch cord (5 qty)
$333.00
NFC-IBC-2.5mm OneClick cleaners for 2.5 mm SC, ST, FC connectors
and patch cord (5 qty)
$333.00
NFC-IBC-MPO OneClick cleaners for MPO connector (5 qty) $451.00
NFC-KIT-CASE-E Enhanced Fiber Optic Cleaning Kit Includes (1)
OneClick cleaner for 1.25mm connectors, (1) OneClick
cleaner for 2.5mm connectors, (1) OneClick cleaner for
MPO connectors, a solvent pen, a cleaning cube and
a soft case
$266.00
1. For 850 nm, 0 dBm to -50 dBm. For 1300, 1310, 1550 nm, -5 dBm to -50 dBm
2. Measured power levels ≤0 dBm. Backlight on. Battery life depends on the condition and type of
batteries used. Fluke Networks recommends alkaline batteries
3. 23°C ±2°C, after 10 minutes of warm-up time.
4. Auto wavelength,SCAN ALL, and backlight on. Battery life depends on the condition and type of
batteries used. Fluke Networks recommends alkaline batteries.
Modes 2 kHz modulated, auto wavelength
Power requirement 2 AA alkaline batteries
Battery life4 >30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.6 in x 3.2 in x 1.6 in
Weight 10.9 oz (309 g)
22
Select an Individual Fiber: Drilling down to a single ber during testing and troubleshooting is always a challenge in data centers. MuliFiber Pro can troubleshoot
a single ber within an MPO trunk to provide a single ber test result. This increases MPO connector verication and troubleshooting exibility with more precise
reporting.